Mechanical Thermostat RTC85

RTC85 series Mechanical Thermostat is mounted in standard wall box.It is adjustable to required temperature from +5/+50℃.

Additional information

Model No.

RTC85

Place of Origin

China

Color

White,Ivory

MOQ

1024pcs

Details about Mechanical Thermostat RTC85

ESUNSIS RTC85 Heating Thermostat Showcase    https://youtu.be/Ilq_emqNnv4

ESUNSIS RTC85 Heating Thermostat Operation    https://youtu.be/Xtyef5LQj4I

 

The indicator is green when the thermostat is on and the indicator turns red when the heating is on. The thermostat is recommended for control of electric heating devices or on/off valve actuator used in water heating systems.

 

RTC85 manual thermostat, designed to be used in underfloor heating system, is to control the temperature of indoor room according to the preset temperature values. If the room temperature drops below the setting temperature, the thermostat will switch the heating device on to warm it up. When the temperature has reached the desired value, the thermostat will turn the heating device off to prevent overheating and wasted energy.

It is easy to operate. The desired temperature can be easily set by rotating the knob in the panel. It is 5℃ to 50℃ adjustable. When the heating is on, the LED indicator glows red. The product design is simple and exquisite, which is perfect for any style of decor.

 

Technical data

Voltage: AC230V (AC110V/AC24V available)

Power consumption: 5W

Setting range: 5~50℃

Switch difference: ±1K

Ambient temperature:-5~50℃

Protective housing: IP20

Housing material: anti-flammable PC

Floor sensor: rubber-thermoplastic NTC sensor, cable length 3m

 

Selection table

 

Model Current Sensor Application
RTC85.13 3A Built-in sensor For control of on/off electric or electro-thermal actuator
RTC85.16 16A Built-in sensor For control of electric heating devices
RTC85.26 16A floor sensor For control of electric heating devices

 

Notice

 

1. The installation must be done after power off.

2. Please connect wires strictly according to the wiring diagram.

3. It is recommended that the installation height should be 1.4m

or be in the same level of other wall switches.

4. If the thermostat displays Er0, the built-in sensor is in breakdown; if the thermostat displays Er1, external sensor is in breakdown.

5. Do not install the thermostat in a non-ventilated position, such

as in the corner, behind the door etc.

6. Do not install the thermostat in a place with strong airflow or

near the cold or heat source.

7. Do not let the water, cement paste, metal particles and other

debris into the thermostat. These will damage the thermostat.

Share Mechanical Thermostat RTC85 With Your Clients

Share to Facebook
Share to Twitter
Share to Linkedin